PROUD TO OFFER PREMIUM DECKING AND PATIO COVERS SINCE 1990

VANCOUVER ISLAND — GREATER VICTORIA BC

ROOFTOP DECK BUILDER
VANCOUVER ISLAND

A rooftop deck above an occupied living space demands more than a standard contractor — it requires a builder who understands structural engineering, waterproofing to a roof-grade standard, drainage design, and BC Building Code compliance for over-habitable-space applications. We are Vancouver Island’s experienced rooftop deck builders, serving Greater Victoria, the West Shore, and the entire island.

32+

Years Experience

1,500+

Projects Completed

20-Year

Manufacturer Warranty

WHY ROOFTOP DECKS NEED A SPECIALIST

WHY ROOFTOP DECK BUILDING IS NOT
A STANDARD CONTRACTING JOB

Most deck contractors build ground-level and elevated decks. A rooftop deck is a fundamentally different scope — it sits directly above a bedroom, living room, garage, or commercial suite, and every drop of water that penetrates the surface enters that occupied space. There is no second chance after a failed rooftop deck. The waterproofing has to be correct from the first day.

A qualified rooftop deck builder on Vancouver Island must understand drainage slope engineering, parapet and curb flashing, heat-welded membrane installation, individual penetration detailing, and BC Building Code structural requirements for loads above occupied space. We have built and waterproofed rooftop decks across Greater Victoria since 1992 — on heritage homes, modern condominiums, commercial buildings, and strata properties.

WHAT OUR ROOFTOP DECK BUILDS INCLUDE

WHAT A QUALIFIED ROOFTOP DECK
BUILDER DELIVERS ON EVERY PROJECT

Not every deck contractor builds to rooftop standard. These are the non-negotiable elements of every rooftop deck project we complete on Vancouver Island.

STRUCTURAL ENGINEERING

Every rooftop deck we build is engineered for the load requirements of its specific application — joist sizing, blocking layout, and framing specifications appropriate for the span and occupancy below.

60+ MIL VINYL MEMBRANE

We specify minimum 60 mil commercial-grade PVC membrane on every rooftop deck — the same weight used in commercial flat roofing. Thinner materials are not appropriate above occupied space.

HEAT-WELDED SEAMS

Every seam in our rooftop membrane is heat-welded to create a single continuous waterproof layer. No adhesive, no tape — heat welding is the only method rated for rooftop over-habitable-space exposure.

ENGINEERED DRAINAGE SLOPE

Every rooftop deck is sloped to drain — minimum 1% across the full field, directing water to correctly sized drains or scuppers. Standing water on a rooftop membrane is the leading cause of premature failure.

PARAPET & CURB FLASHING

All parapet walls, roof curbs, and vertical transitions receive full membrane upstand flashing — taken minimum 150mm above the finished deck surface and mechanically fastened.

FLOOD TEST BEFORE SIGN-OFF

We flood-test every rooftop deck before declaring the build complete — blocking drains and ponding water for minimum 24 hours to confirm zero leakage into the space below.

ROOFTOP DECK BUILD TYPES

ROOFTOP DECK BUILDS WE COMPLETE
ACROSS VANCOUVER ISLAND

We build rooftop decks on every property type across Greater Victoria — from single-family homes to strata buildings and commercial properties.

RESIDENTIAL

STRATA & MULTI-FAMILY

COMMERCIAL

OUR BUILD PROCESS

HOW WE BUILD ROOFTOP DECKS
ON VANCOUVER ISLAND

From your first call to a flood-tested, warranty-registered rooftop deck — here is exactly what to expect when you hire us as your Vancouver Island rooftop deck builder.

01

SITE ASSESSMENT & SPECIFICATION

We assess the rooftop structure, drainage configuration, parapet heights, penetration locations, and occupancy below — then specify the correct membrane weight, drain sizing, and framing requirements for your specific project.

02

STRUCTURAL BUILD

Framing, blocking, and sheathing are installed to BC Building Code structural requirements for the load and span of your specific application. All drain rough-ins are positioned at correct low points before sheathing closes.

03

MEMBRANE INSTALLATION

Field sheets are laid, all seams heat-welded, membrane turned up parapets and curbs to correct height. Drains, penetrations, and door transitions are individually detailed — no exceptions, no shortcuts.

04

FLOOD TEST & SIGN-OFF

Drains are blocked and the rooftop is flooded for minimum 24 hours. The space below is inspected for moisture. Only a passed flood test triggers sign-off and 20-year manufacturer warranty registration.

WHY CHOOSE US AS YOUR ROOFTOP DECK BUILDER

WHY VICTORIA HOMEOWNERS &
STRATA COUNCILS CHOOSE US

A rooftop deck above an occupied space is one of the highest-stakes building projects on any property. Getting it wrong means water damage to the structure below — often hidden for months before it reveals itself as a stained ceiling, rotted joist, or mould in a wall cavity.

We have specialized in rooftop deck building and waterproofing on Vancouver Island since 1992. Our flood-test standard means we never hand over a rooftop deck we have not confirmed watertight by an actual water test — not a visual inspection, not a spray test, but a minimum 24-hour full flood.

WHAT SETS US APART:

SERVICE AREA

ROOFTOP DECK BUILDER SERVING
ALL OF VANCOUVER ISLAND

We build rooftop decks throughout Greater Victoria and all of Vancouver Island — residential, strata, and commercial projects of every scale.

Anywhere on Vancouver Island — call (250) 201-2193 to discuss your rooftop deck project.

BUILD IT RIGHT THE FIRST TIME

TALK TO VANCOUVER ISLAND'S ROOFTOP
DECK BUILDER TODAY

Free site assessment, detailed written quote, 24-hour flood test on every project, and a 20-year manufacturer warranty. No shortcuts above occupied space.